Operating temperature max.
120 °C
Design
analog
flow rate measuring device
with load unit incl. manometer, thermometer, load pressure build-up valve, overload protection
Media
mineral oil
გთხოვთ, აირჩიოთ ვარიანტი
მახასიათებლები
Operating temperature max.
- 120 °C
Design
- analog
- flow rate measuring device
- with load unit incl. manometer, thermometer, load pressure build-up valve, overload protection
Media
- mineral oil
Material
- stainless steel housing
Max. working pressure
- max. 350 bar
Application
- Measurements of volumetric flow, pressure and temperature, performance of hydraulic systems
Customs tariff number
- 90269000
ყველა მახასიათებელი
Product description
Notes
Caution! Throttle valve of the load unit must be completely open in the beginning of the test and must not be completely closed during operation!
Description
Linear display scale in l/min. One flow direction.
Sturdy and resistant to shock and vibration.
Accuracy ±2 % of full scale value.
Housing 360° rotatable.
Pre-assembled load unit with load pressure build-up valve incl. replaceable overload protection for unit protection (breakage of the overload protection without oil leakage at 420 bar).
Pressure gauges with glycerine filling.
Thermometer can be removed from pressure sleeve.
Ideal for service checks of pumps and motors as well as pressure and flow valves in hydraulics.
Delivery scope
პროდუქტის ვარიანტები